Zinc layer Z120 standard, strong weather resistance, suitable for plant, warehouse roof and wall enclosure system.
Product overview
Galvanized steel coil is cold-rolled or hot-rolled steel coil as the base material, processed by hot-dip galvanized process of high anticorrosion coil, the surface zinc layer is uniform and dense, both steel strength and zinc layer corrosion resistance, widely used in construction, home appliances, automobiles and outdoor facilities.
Core technology
Mechanical property
Performance index | Parameter range | enforce standards |
---|---|---|
Tensile strength (MPa) | 270-500 (SPCC/Q235B substrate) | GB/T 2518, ASTM A653 |
Yield strength (MPa) | 140-340 | JIS G3302, EN 10346 |
Elongation (%) | 18%-35% | Zinc layer adhesion test passed |
Amount of zinc layer adhesion | 60-275g/㎡ (double-sided) | The Z60/Z120/Z275 can be customized |
Executive standard control
Standard type | Standard number (example) | Application scenario |
---|---|---|
China national standard | GB/T 2518(DX51D+Z) | Building roof, universal anticorrosion |
American standard | ASTM A653(CS Type B) | Auto parts, structural parts |
Japanese standard | JIS G3302(SGCC) | Home appliance shell, precision stamping |
European standard | EN 10346(DX51D+Z) | Industrial equipment, cross-border trade |
Chemical composition (Substrate example: SPCC)
element | Content range | effect |
---|---|---|
碳(C) | ≤0.12% | Control strength and ductility balance |
锰(Mn) | ≤0.50% | Improve the toughness of the substrate |
磷(P) | ≤0.035% | Too much can lead to cold and brittle |
硫(S) | ≤0.035% | Affect welding performance |
锌层(Zinc layer Zn) | ≥99.9% | Core anti-corrosion components, prevent water and oxygen corrosion |
Technical parameter
Usage and application scenarios
Construction field:
Automobile manufacturing:
Home appliance industry:
Agricultural facilities:
Industrial equipment:
Product advantage
✅ Super corrosion resistance:
There is a zinc layer on the surface of the material, which can effectively isolate the corrosive medium, which means that the material can remain stable and not easily corroded, even in harsh environments such as humidity, acid rain or salt spray. For example, in coastal areas or in places with severe corrosive environments such as chemical plants, this material can maintain stable performance for a long time.
✅Easy processing:
The material supports a variety of processing processes, such as cutting, stamping, bending and welding, which means that during manufacturing and use, the material can be flexibly processed and formed to meet different design and use needs. For example, when manufacturing auto parts or building structures, materials can be easily cut, bent and welded.
✅ Environmental safety:
The material complies with the RoHS (Restriction of Hazardous Substances Directive) and REACH (Registration, Evaluation, Authorization and Restriction of Chemicals Regulation) standards, does not contain harmful substances such as heavy metals, and has little impact on the environment and human health. This means that during the production and waste process, the material will not cause serious pollution to the environment, and it is safer and more reliable to use.
✅ High cost performance:
The material has anti-corrosion properties and does not require additional maintenance measures, thus costing less than ordinary steel throughout its life cycle. This means that while the initial investment may be higher, the total cost is actually lower in the long run due to reduced frequency of maintenance and replacement. For example, in long-term projects such as Bridges and buildings, the use of this material can reduce maintenance costs and improve economic efficiency.
Frequently Asked Questions (FAQ)
Q1: How to choose galvanized coil with different thickness of zinc layer?
The galvanized coil with different thickness of zinc layer is suitable for different corrosive environment, the specific choice is as follows:
Z60: suitable for mildly corrosive environment, such as indoor dry environment.
Z120: Suitable for conventional outdoor use, such as building roofs.
Z275: Suitable for harsh corrosion scenarios, such as coastal areas or chemical plants.
Q2: Can the galvanized coil be welded or sprayed directly?
The galvanized coil can be welded, but the zinc layer in the welding area needs to be removed before welding.
Galvanized coil also supports spraying, but it is recommended to phosphating before spraying to improve the adhesion of the coating.
Q3: What should I pay attention to when transporting and storing galvanized coils?
When transporting and storing galvanized rolls, avoid rain. When stacking, moisture-proof paper should be placed between the layers. If it needs to be stored outdoors, it should be covered with rain cloth.
Performance pledge
Quality assurance: Provide third-party SGS test report, warranty period of 10 years.
Flexible customization: Support zinc layer weight, size, surface treatment process personalized customization.
Fast delivery: 72 hours delivery for conventional specifications, 7-15 days production cycle for special needs.
In the initial phases, architects and designers play a crucial role in conceptualizing and designing projects, ensuring they align with both aesthetic and functional requirements.
After price confirmed, FREE SAMPLE could be provided for your evaluation. After you confirm the sample details, the samples will be ready for delivery in 3-7days, and will be sent to you via express and arrive in 3-5days.1
Yes, our company mainly deals with wholesale deals, but if you insist buying one piece, or you just need one piece, we would be very likely to make the MOQ as 1 piece for you though.
Our company has been in Alibaba.com for 11 years, which is longer than most of our fellow suppliers, we've been golden suppliers for years. What's more, we've got quite a lot authority certificates, for example, BV, ISO9001, API, Alibaba onsite check cert